How To Calculate Air Conditioner Size
Air conditioners are rated in BTU per hour, which is a heat removal rate rather than a weight or a size. Getting the number right stops you buying a unit that cannot keep up, or one that is so oversized it never runs long enough to dehumidify.
Quick Answer
BTU = area x 20 x (ceiling height / 8) x climate factor x kitchen factor
- area
- The floor area of the room, in square feet
- 20
- The baseline BTU per square foot at 8 foot ceilings
- climate
- A factor above or below 1 for hot or mild regions
- tons
- BTU per hour divided by 12,000
Start from twenty BTU per square foot at 8 foot ceilings, then adjust for ceiling height, climate and kitchens. A 300 square foot room with 8 foot ceilings needs 6,000 BTU per hour, which is 0.5 tons and draws about 7.326775966533632 amps on a 240 volt circuit.
What Is Air Conditioner Size?
A BTU per hour is a rate of heat removal, and 12,000 of them is one ton of cooling. The ton comes from the amount of heat needed to melt a ton of ice in a day, and it survives in the trade because a ton maps neatly onto a whole-number BTU.
The baseline figure is twenty BTU per square foot per hour for an 8 foot ceiling. A 300 square foot room therefore starts at 6,000 BTU, which is exactly half a ton.
Ceiling height matters because the volume scales with it. Doubling the height doubles the air that needs cooling, so the factor is simply the ceiling height divided by the baseline of eight feet.
Climate adjustment shifts the baseline up or down. A hot, humid region usually adds ten percent, while a mild climate can drop ten percent, and the difference between those two on a 6,000 BTU room is 1,200 BTU either way.
Kitchens add their own load. Cooking appliances dump heat and moisture into the room, so a kitchen gets an extra factor on top of the climate adjustment. A garage or a sunroom behaves similarly and deserves the same bump.
The four multipliers stack. A 300 square foot room with 9 foot ceilings, a hot climate and a kitchen comes to 300 times 20 times 1.125 times 1.1 times 1.1, which is 8,167.5 BTU per hour.
Oversizing is a real problem, not a safe default. A unit that is too big cools the air quickly and shuts off before it has removed much moisture, leaving the room cold and clammy. The compressor then short-cycles, which shortens its life.
Undersizing shows up differently. The unit runs continuously and still cannot reach the set temperature, which is uncomfortable, expensive and hard on the compressor.
Window units come in 5,000 BTU steps, so you round to the nearest available size. A 6,000 BTU requirement maps to a 6,000 BTU window unit; a 6,800 BTU requirement usually means buying the 8,000 BTU class.
Electrical checks come after the BTU number. Multiply the BTU by 0.293 to get watts, then divide by the circuit voltage to get amps. A 6,000 BTU unit draws about 7.326775966533632 amps on a 240 volt circuit, which is well within a 15 amp breaker.
Insulation and window area are the biggest missing factors. A well-insulated modern room with double glazing sits below the baseline, while an older room with large single-glazed south-facing windows sits well above it. The twenty BTU figure is a compromise that assumes average construction.
Occupancy and equipment add heat that the baseline ignores. Each person in the room contributes a few hundred BTU, and computers, televisions and lighting all add to the load. A home office with two monitors and a desktop can need an extra step of unit size.
Ducted and central systems are sized differently from window units. A central system serves the whole house and is sized with a manual calculation including duct losses, while a window or through-wall unit is sized room by room with the simple baseline.
The seasonal energy efficiency ratio tells you how much cooling you get per watt. A higher ratio unit costs more but draws less current for the same BTU, which is why the electrical draw is not simply proportional to the BTU rating.
Portable units need a bigger BTU rating than window units for the same room, because they are less efficient and dump some heat back into the room. Adding roughly twenty percent to the BTU figure is the usual correction for a single-hose portable.
Running cost follows from the BTU and the hours. A 6,000 BTU unit running eight hours a day draws on the order of a few hundred watt-hours, and at typical electricity rates that is a modest daily cost but a noticeable monthly one in a hot spell.
Zoning matters in open plan homes. A single large unit trying to cool a whole floor often underperforms, and two smaller units serving separate zones cool better and cost less to run than one large one.
Maintenance keeps the rating honest. A clogged filter can cut capacity by a noticeable percentage, so a unit that was correctly sized when new ends up undersized when dirty, and the symptom looks like the sizing was wrong.
Formula
base BTU = area x 20
Formula page →Twenty BTU per square foot per hour, for an 8 foot ceiling in a temperate climate.
| Symbol | Meaning | Unit | Notes |
|---|---|---|---|
| Q0 | Baseline load | BTU per hour | The heat removal rate before adjustments. |
| A | Area | square feet | The floor area of the room. |
| 20 | Baseline rate | BTU per sq ft per hour | BTU per square foot per hour. |
BTU = area x 20 x (ceiling height / 8) x climate factor x kitchen factor
Formula page →The four multipliers capture volume, weather and internal heat sources.
| Symbol | Meaning | Unit | Notes |
|---|---|---|---|
| Q | Cooling load | BTU per hour | The heat removal rate the unit must deliver. |
| A | Area | square feet | The floor area of the room. |
| h | Ceiling height | feet | The height of the ceiling, usually 8 to 12 feet. |
| f | Factors | unitless | Climate and kitchen adjustments, around 1 each. |
amps = BTU / 3.412142 / voltage
Formula page →Converts the cooling rate to electrical current at the circuit voltage.
| Symbol | Meaning | Unit | Notes |
|---|---|---|---|
| I | Current | amps | The electrical draw of the unit. |
| Q | Cooling load | BTU per hour | The heat removal rate. |
| 3.412142 | BTU to watts | unitless | One watt equals 3.412142 BTU per hour. |
| V | Voltage | volts | The circuit voltage, usually 120 or 240. |
How To Calculate Air Conditioner Size
- 1
Measure the floor area
Length times width for a rectangular room, and split an L-shape into two rectangles. A 15 by 20 foot room is 300 square feet.
- 2
Take twenty BTU per square foot
The baseline for a temperate climate and an 8 foot ceiling. Three hundred square feet gives 6,000 BTU per hour.
- 3
Adjust for ceiling height
Multiply by the ceiling height divided by 8. A 10 foot ceiling multiplies the load by 1.25, taking 6,000 BTU up to 7,500.
- 4
Apply the climate and kitchen factors
Typically 1.1 for a hot climate and another 1.1 for a kitchen, applied on top of the height factor.
- 5
Round to a whole unit size
Window units come in 5,000 BTU steps, so round up rather than down. Then check the electrical draw against the circuit.
Examples
Example 1: A 300 square foot bedroom with 8 foot ceilings
- Room area
- 300
- Ceiling height
- 8
- Climate
- Temperate
- Kitchen
- No
| Step | Calculation | Result |
|---|---|---|
| Baseline rate | 20 | 20 |
| Height factor | 8 / 8 | 1 |
| Climate factor | 1 | 1 |
| Kitchen factor | 1 | 1 |
| Cooling load | 300 x 20 x 1 x 1 x 1 | 6000 |
| Tons of cooling | 6000 / 12000 | 0.5 |
| Cooling watts | 6000 / 3.412142 | 1758.4262319680718 |
Result: A 300 square foot bedroom with 8 foot ceilings needs 6,000 BTU per hour, which is 0.5 tons of cooling and about 1758.4262319680718 watts of cooling capacity.
Example 2: An 800 square foot open plan kitchen in a hot climate
- Room area
- 800
- Ceiling height
- 8
- Climate
- Hot
- Kitchen
- Yes
| Step | Calculation | Result |
|---|---|---|
| Baseline rate | 20 | 20 |
| Height factor | 8 / 8 | 1 |
| Climate factor | 1.1 | 1.1 |
| Kitchen factor | 1.1 | 1.1 |
| Cooling load | 800 x 20 x 1 x 1.1 x 1.1 | 19360 |
| Tons of cooling | 19360 / 12000 | 1.6133333333333333 |
| Cooling watts | 19360 / 3.412142 | 5673.855308483645 |
Result: An 800 square foot open plan space with a kitchen in a hot climate needs 19,360 BTU per hour, which is 1.6133333333333333 tons and about 5673.855308483645 watts, so a 2 ton unit is the right class.
Example 3: A 150 square foot room with 9 foot ceilings
- Room area
- 150
- Ceiling height
- 9
- Climate
- Mild
- Kitchen
- No
| Step | Calculation | Result |
|---|---|---|
| Baseline rate | 20 | 20 |
| Height factor | 9 / 8 | 1.125 |
| Climate factor | 0.9 | 0.9 |
| Kitchen factor | 1 | 1 |
| Cooling load | 150 x 20 x 1.125 x 0.9 x 1 | 3037.5 |
| Tons of cooling | 3037.5 / 12000 | 0.253125 |
| Cooling watts | 3037.5 / 3.412142 | 890.2032799338364 |
Result: A 150 square foot room with 9 foot ceilings in a mild climate needs 3,037.5 BTU per hour, which is 0.253125 tons and about 890.2032799338364 watts of cooling, so a 5,000 BTU window unit covers it with room to spare.
Calculator
Cooling load
6,000
- Tons of cooling
- 0.5
- Cooling capacity in watts
- 1,758.4262
- Current draw at 240 volts
- 7.3268
- BTU per square foot
- 20
Values update as you type. This calculator covers the single scenario its formula assumes — see Common Mistakes for what it leaves out.
Prefer a full-width tool? Open the Air Conditioner Size calculator page.
Common Mistakes
Using square footage alone and ignoring ceiling height
A 10 foot ceiling holds 25 percent more air than an 8 foot one, and the load scales with it. Twenty BTU per square foot only holds at the baseline height.
Buying the biggest unit available
Oversized units short-cycle and cool without dehumidifying, leaving the room cold and damp. Match the load rather than exceeding it by a wide margin.
Skipping the kitchen factor
An oven and a hob dump real heat into the room. A kitchen without the extra factor ends up with a unit that runs constantly on a hot afternoon.
Confusing BTU with watts
A BTU per hour is a rate of heat removal, not an electrical rating. Converting needs the 3.412142 factor, and the electrical draw also depends on the efficiency.
Applying a single ton per X square feet rule too rigidly
The twenty BTU per square foot baseline is a starting point, not a law. Insulation, window area and sun exposure all move the real number.
Ignoring the circuit rating
A large unit on a 15 amp circuit will trip the breaker. Check the draw against the breaker before buying, especially on an older 120 volt socket.
FAQ
How many BTU do I need for 300 square feet?
About 6,000 BTU per hour at 8 foot ceilings, which is half a ton of cooling. Add for taller ceilings, a hot climate or a kitchen.
How many BTU per square foot do I need?
Twenty BTU per square foot per hour is the usual baseline for an 8 foot ceiling in a temperate climate.
How many BTU is one ton of cooling?
12,000 BTU per hour, which came from the heat needed to melt a ton of ice in a day.
What size air conditioner do I need for a 200 square foot room?
Around 4,000 BTU per hour, which usually means a 5,000 BTU window unit since those come in 5,000 BTU steps.
Do higher ceilings need more BTU?
Yes, in direct proportion. A 10 foot ceiling needs 1.25 times the load of an 8 foot ceiling over the same floor area.
How much power does a 6,000 BTU air conditioner use?
Roughly 1,758.4262319680718 watts of cooling, which at 240 volts draws about 7.326775966533632 amps. The electrical input is higher once compressor efficiency is accounted for.
References
- [1]Wikipedia, British thermal unit — https://en.wikipedia.org/wiki/British_thermal_unit
- [2]Wikipedia, Ton of refrigeration — https://en.wikipedia.org/wiki/Ton_of_refrigeration
- [3]ENERGY STAR, Air conditioner sizing guidance — https://www.energystar.gov/products/heating_cooling/air_conditioning_central